Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the premium-addons-for-elementor domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/u800375974/domains/technoline-ca.com/public_html/wp-includes/functions.php on line 6114
Techno PRO 1200VA – Technoline

Techno PRO 1200VA

Techno PRO 1200VA

Part Number :TP1200Li

Desciption:

Main Specifications:

• Personal Computer, Modem, Local Area Networks Video Surveillance Systems

• Automatic Voltage Regulation circuit (AVR) • Output sockets for blackout protection

• Output sockets for overvoltage protection

• Cold start function

• Compatible generators

• LCD display (power line status and residual backup time)

Model Techno Pro 1200 Techno Pro 1500 Techno Pro 2000
Capacity (VA/Watts) 1200/720 1500/900 2000/1200
INPUT
Nominal Input Voltage 110/120Vac or 220/230/240 Vac
Operating Voltage Range 81-145Vac/162-290 Vac
Operating Frequency Range 50/60 Hz (1±10%)
OUTPUT
Output Voltage range (Batt. Mode) Simulated Sinewave  at nominal voltage ±10%
Frequency Range (Batt. Mode) 50 Hz or 60 Hz ± 1 Hz
Transfer Time Typical 2-6 ms, 10ms max.
BATTERY
Battery Type & Number 12 V / 7.2Ah x 2 12 V / 9 Ah x 2 12 V / 9 Ah x 2
Typical Recharge Time 6-8 hours ( To 90%  capacity)
PROTECTION
Full Protection Overload and overcharge protection
INDICATORS
Indicators AC Mode, Battery Mode, Load Level, Battery Level

AC Mode, Battery

Mode, Load Level,

Battery Level, Input  Voltage, Output

Voltage, Overload,

Fault, Battery Low

ALARM
Battery Mode Sounding every 10 seconds
Battery Low Sounding every second
Overload Sounding every 0.5 second
Battery Replacement Alarm Sounding every 2 seconds
Fault Continuously sounding
Management
USB & RS-232 port(Optional)

USB or RS232(Supports Windows    2000/2003/XP/Vista/2008,

Windows  7, Linux, Unix, and MAC)

LCD UPS status, input/output voltage, input/output frequency, load level, battery capacity, and warning or fault error code.
Environment
Operating Temperature 0- 40°C
Humidity Range 0-95 % (Non-condensing)
Noise Level <45db (1 meter from surface)
PHYSICAL
Dimension, W x D x H (mm) 312*122*195 360*122*195 360*122*195
Net Weight (kg) 8.8 11.7 13.1
STANDARDS
Safety IEC/EN62040-1;IEC/EN60950-1
EMC

IEC/EN62040-2;IEC61000-4-2;IEC61000-4-3;IEC61000-4-4;IEC61000-4-

5;IEC61000-4-6;IEC61000-4-8