EVP RT PLUS T3 20.0

EVP RT PLUS T3 20.0

Part Number :TLEVP20-RT

Desciption:

  • Complete protection from blackout, voltage fluctuations (overvoltages and undervoltages), lightning (with upstream arrester), frequency variations, surge, harmonics, voltage distortions
  • Recommended for Local Area Networks (LAN), Data Centers, Industry, Electromedical Equipments
  • Power factor 1
  • LCD Touch graphic display
  • Double input mains/bypass
  • Intelligent slot for SNMP, Dry Contact or MODBUS card
  • On-Line Double Conversion technology transformerless (VFI-SS-111)
  • Active PFC circuit (0.99)
  • Compatibility with generator
  • Static and manual bypass
  • Frequency converter mode
MODEL

TLEVP10-RT

TLEVP15-RT

TLEVP20-RT

Capacity (VA/Watts)

10k/10k

 15k/15k

20k/20k

INPUT 
Nominal Voltage

380/400/415 (3Ph+N+PE)

Operating voltage range

138~485Vac for 40%load; 305~485Vac for full-load

Operating frequency range

40~70Hz

Power Factor

≥0.99

Harmonic distortion (THDi)

≤3% (100% linear load)

 Bypass input 
Bypass voltage range

Max. voltage:220V: +25%(optional +10%,+15%,+20% ) ;
230V: +20%(optional +10%,+15% ) ;
240V: +15%(optional +10%)
Min. voltage: -45% (optional -10%,-20%,-30%)

Bypass Frequency range

Frequency protection range: ±10%

Generator input

Support

OUTPUT  
Output Voltage

380/400/415Vac,(3Ph+N+PE)

Power Factor

1.0

Output frequency(Hz)

Line mode:Synchronize with input ;when input frequency >±10%%(±1%、±2%、±4%、±5% Optional,
Output frequency 50×(1±0.1%)Hz Battery mode :(50/60±0.1%)Hz

Waveform

Pure sine wave

Crest factor

3:1

Harmonic distortion(THDV)

≤2%(100% linear load); ≤4% (100% non linear load)

Transfer Time(ms)

0 Ms

Efficiency

UP to 95

Overload

≤110% overload for 60 min; 125% overload for 10 min; ≤150% overload for 1 min

Bypass Mode

135% overload for long term; >1000% overload for 100 ms

BATTERY
Battery Voltage

For optional : Optional Voltage: ±180/192/204/216/228/
240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/
46/48/50pcs optional); 360Vdc~600Vdc (30~50 pcs, 30 pcs default, 36~50 pcs fully output ; 32~34 pcs
Out put power factor 0.9; 30 pcs output power factor 0.8;)

Max charger current (A)

18

20

 Others
 Alarm function

    Overload、utility abnormal、UPS fail、battery low voltage etc

 Protection function

 Short circuit、overload、overheat、battery low、output low voltage、fan fault、Anti-thunder

SYSTEM FEATURES
Overload Line Mode

Load≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, ≥150% turn to bypass mode immediately

Bat. Mode

Load≤110%: last 10min, ≤125%: last 1min, ≤150%: last 5S, ≥150% shut down UPS immediately

Bypass Mode<40℃<=”” style=”box-sizing: border-box;”>

Breaker( Load < 125%, long-term operation)

Short circuit

Hold whole system

Communication interface

RS232, RS485, Parallel, Intelligent Slot(SNMP card/ Relay card(optional)),
BMS (optional),EPO port, Output port, MAINTAIN-AUXSWS

PHYSICAL 
Dimension W×H×D (mm)

443×131(3U)x580 mm

Net Weight (kg)

29

31

32

ENVIRONMENT
Operating temperature

0~40℃

Storage  temperature

-25℃~60℃

Humidity range

0~95% (non-condensing)

Altitude

<1500m(when excess 1500m, according to GB/T 3859.2 to derating)

Noise Level

<55db

STANDARDS
Safety 

IEC/EN62040-1,IEC/EN60950-1

EMC

 IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8